Module guide · Available

Phase Equilibrium: which phases coexist, and in what amounts

When does a liquid mixture start to boil, what is the first vapour made of, and how much vapour forms at a given temperature and pressure? This module applies pure-component and mixture thermodynamics to vapour–liquid equilibrium, and teaches how to read the diagrams that summarise it.

Part of Chemical Engineering Thermodynamics. Builds on Pure Component Properties and Solution Thermodynamics.

The question this module answers

Distillation, flash drums, evaporators and condensers all exploit the same fact: when a liquid mixture partly vaporises, the vapour and liquid usually have different compositions. The exception is an azeotrope, where the two compositions are equal and simple distillation can go no further. Predicting those compositions, and the conditions at which boiling starts and ends, is the starting point for every separation that uses vapour and liquid.

Phase Equilibrium asks one question in three forms: at what conditions can vapour and liquid coexist, with what compositions, and in what amounts?

Before you start

Vapour pressure and fugacity from Pure Component Properties; activity coefficients, mixture fugacity coefficients and chemical potential from Solution Thermodynamics; and mole-fraction material balances.

The equilibrium condition

Vapour and liquid are in equilibrium when each component has the same fugacity in both phases. Every calculation in the module starts from that condition and expresses it through an equilibrium ratio:

f̂iL = f̂iV  (i = 1, …, N)   Ki = yi/xi

The chosen formulation decides how each phase fugacity, and therefore each K value, is evaluated. The type of problem decides which variable is unknown and which closure condition, such as Σyi = 1, completes the solution.

Three topics from one foundation

Pure-component and mixture inputsvapour pressure, activity and fugacity coefficients
Vapour–liquid equilibriumequal component fugacities
P–xyfixed temperature: bubble and dew pressures T–xyfixed pressure: bubble and dew temperatures Flash calculationsgiven T, P and feed: phase state and amounts
P–xy, T–xy and flash are sibling problems built on the same equilibrium foundation. None feeds the others; the dashed box is context from earlier modules. Both diagram topics also offer a companion x–y view of the same equilibrium pairs.

Suggested study order: a learning progression, not a scientific dependency

  1. P–xy
  2. T–xy
  3. Flash calculations

P–xy introduces the diagrams with the simplest calculation. T–xy adds a temperature search, because vapour pressures depend on temperature. Flash then combines equilibrium ratios with an overall material balance for a specified feed.

Bubble and dew questions

Five standard calculations are supported. In each, two variables are fixed and the remaining ones are found.

The five vapour–liquid calculation classes
CalculationGivenFind
BUBL PT, liquid xbubble pressure and first-vapour y
DEW PT, vapour ydew pressure and last-liquid x
BUBL TP, liquid xbubble temperature and first-vapour y
DEW TP, vapour ydew temperature and last-liquid x
TP flashT, P, overall zphase state, vapour fraction, x and y

The calculations differ in difficulty. With modified Raoult’s law, a bubble pressure needs no iteration because temperature and liquid composition fix the activity coefficients. A dew pressure does: the liquid composition is unknown, so it and its activity coefficients are updated until they agree. Bubble and dew temperatures add a search in temperature, because every vapour pressure changes with it. The Blackboard shows the iterations that the engine actually performs.

Reading P–xy, T–xy and x–y diagrams

Binary phase diagrams are new to many students, so the module treats reading them as a skill in its own right.

  • Axes and endpoints. Composition, usually the mole fraction of component 1, runs from 0 to 1. On a P–xy diagram at fixed temperature the curves end at the two pure-component vapour pressures; on a T–xy diagram at fixed pressure they end at the two boiling temperatures.
  • Bubble and dew curves. The bubble curve is plotted against liquid composition and the dew curve against vapour composition. On P–xy, liquid lies above the bubble curve and vapour below the dew curve. On T–xy the picture is inverted: liquid lies below the bubble curve and vapour above the dew curve.
  • Tie lines and the lever rule. Between the curves, a horizontal line at one pressure (or temperature) meets the bubble curve at the liquid composition and the dew curve at the vapour composition. For an overall composition on that line, the relative distances to the two ends give the phase amounts.
  • Changing conditions at fixed overall composition. Lowering the pressure on P–xy, or raising the temperature on T–xy, moves a mixture from the first bubble to the last drop of liquid along a vertical line.
  • Azeotropic signatures. Where the model predicts it, the bubble and dew curves touch at a pressure maximum or minimum (or a temperature minimum or maximum). The platform plots what the model predicts on a finite grid; it does not search for an exact azeotrope.
  • The x–y view. Plotting equilibrium y1 against x1, with the diagonal y1 = x1 for reference, shows enrichment directly. Each point keeps the fixed temperature or pressure of its parent diagram.

Flash: phase state and amounts

At specified temperature, pressure and overall composition, which phases exist and how much of each forms?

The feed is first placed against its own bubble and dew pressures at the specified temperature. Above the bubble pressure it is a single liquid; below the dew pressure, a single vapour. Both are valid equilibrium answers, not failures. Between them the feed splits, and the vapour fraction V follows from the Rachford–Rice material balance:

Σ zi(Ki − 1) / [1 + V(Ki − 1)] = 0   xi = zi / [1 + V(Ki − 1)],  yi = Kixi

Flash supports two to five components where the chosen formulation and data allow. A flash-drum view places the same result in a process setting; it is not a vessel or hydraulic design.

Four formulations

The same problems can be solved with four descriptions of the two phases. They are routes through every topic, not separate topics.

Vapour–liquid formulations
FormulationLiquidVapourTypical use
Raoult’s lawideal solutionideal gasintroductory baseline for similar molecules at low pressure
Modified Raoult’s lawactivity coefficientsideal gasnon-ideal liquids at low pressure
γ–φactivity coefficients and reference-state correctionsfugacity coefficientsnon-ideal liquids where vapour non-ideality also matters
φ–φcubic equation of statethe same cubic equationsystems an equation of state represents well, including higher pressures

Henry’s law is not a fifth formulation. It is a reference for a dilute dissolved gas within an activity-based formulation, available where solvent-specific Henry data exist (for example carbon dioxide in water at low pressure) and restricted to the dilute range those data support.

Models and data choices

  • Activity models: Margules, Van Laar, Wilson, NRTL and original UNIFAC, taken from Solution Thermodynamics rather than re-derived.
  • Parameters for P–xy and T–xy: library or custom binary parameters, chosen explicitly.
  • Parameters for flash: a valid library pair is used where available, otherwise a UNIFAC-estimated pair for the same model; if neither exists, the calculation is unavailable.
  • Equation-of-state interaction: a library kij where available, or kij = 0 stated as an approximation; the value and its source travel with the result.

Missing data never trigger a silent switch to ideal behaviour, and a failed iteration never produces an invented point on a diagram.

Worked example: ethanol–water P–xy

The published ethanol–water P–xy worked example takes an equimolar liquid at 343.15 K and finds its bubble pressure, 0.6791 bar, and first-vapour composition, yethanol = 0.6626, with modified Raoult’s law and NRTL. It sets out the inputs, parameter sources, each Blackboard step, the diagram and the limits of the result, and ends with the settings to reproduce it in the platform.

Common misunderstandings

  • “The first-vapour composition is the product.” At the bubble point the vapour is vanishingly small. How much vapour forms, and its composition, needs a flash at other conditions.
  • “If K > 1 for a component here, it is enriched everywhere.” K values depend on composition; beyond an azeotrope the enrichment reverses.
  • “A fixed-temperature x–y curve can be used to step off column stages.” Each point of a P–xy diagram is at a different pressure. Column design needs constant-pressure equilibrium data together with operating and balance specifications.
  • “The bubble pressure is the design pressure.” It is a thermodynamic boundary. Pump, storage and vessel margins are separate engineering decisions.

Scope and limits

  • Vapour–liquid only. Liquid–liquid, vapour–liquid–liquid, solid–liquid and other specialised equilibria are not offered.
  • No general phase-stability test. Flash classifies a feed against its bubble and dew boundaries; where that picture is ambiguous, the result is reported as unavailable rather than guessed.
  • Binary diagrams. P–xy and T–xy are for two components; flash handles two to five.
  • Not included: dedicated azeotrope searches, adiabatic flash, advanced equation-of-state mixing rules, mixed-solvent Henry treatments, combined reaction and phase equilibrium, and column or equipment design.
  • Model results. A converged calculation satisfies the model’s equations; it does not show that the model fits the real mixture. Broad validation against experimental data is not claimed.

Sources and next steps

  • J. M. Smith, H. C. Van Ness, M. M. Abbott and M. T. Swihart, Introduction to Chemical Engineering Thermodynamics, 9th ed., chapter 13 (thermodynamic formulations for vapour–liquid equilibrium, including modified Raoult’s law and bubble and dew calculations).
  • This guide summarises ChETL’s documented module scope as of 9 November 2026; editorial responsibility rests with the ChETL Scientific Editor. See sources, review and limits; report errors through Contact.

Launch ChETL

Launch ChETL